DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Upgrading R5r/R6r/R7r to R8r without Adding Memory
2-14Upgrade the software and hardware
2
Verify Interchange (H/C only)
1. Type status spe and pr e s s Enter to m ake sure the stand by si de is re ady for
interchange:
The Standby Refreshed field s hows yes
The Standby Shadowing field s hows on
The Standby Handshake field s hows up
If the stand by SPE d oes n ot full y retu rn to s ervic e, re fer to the STBY- SPE
Maintenance Object sec tion in the
Maintenance
book.
Upgrade Other Carrier (H/C only)
To upgr ade t he oth er ca rrier , loc k the SPE s witc hes on the DU PINT to t he oth er
carrier.
NOTE:
The new active carrier resets (reset 1). Wait until the login prompt ap pears,
then log in.
Repeat the steps from Check the Active Tone-Clock (H/C only) through Verify
Interchange (H/C only).
Affix position label(s)
1. Place the new strip label(s) over the ol d carrier label(s).
Verify software version
NOTE:
The Tape Resident field shows the software load number. Write it down
for use later.
If standard reliability:
1. Type list configuration software-version and press Enter to verify that the
removable media contains the Release 8 software.
If high or critical reliab ility:
1. Type list configuration software-version long and press Enter to verify
that the removable media contain s the Release 8 software.