Adding or Removing Cabinet Hardware
6-45Add IP Interface Assembly
6
Add IP Interface Assembly
DEFINITY ECS IP Solutions allows you to send voice and fax from the DEFINITY
ECS through an Internet protocol (IP) network to other DEFINITY ECSs having
this feature or to other H.323 V2 compliant endpoints . It is implemented using the
TN802/B IP Interface, which is a Windows NT server residing on the I P Interface
Assembly inside the DEFINITY ECS.
The IP Interface is an assembly comp osed of a TN802B circuit board , a
processor card, and DSP resource card. For ordering purp oses, the assembly is
identified as a J58890MA-1 L30, b ut for simplicity, we refer to it in this book as the
TN802B IP Interface.
The TN802B IP Interface operates in two modes: IP Trunk, available with Release
7 or later, and Media Processor (MedPro), available with Release 8. The IP Trunk
mode is Internet Telephone Server—Enterprise (ITS-E) compatible, and the
MedPro mode is H.323 V2 compatib le. The TN802B IP Interface is backwards
compatible and defaults to IP Trunk mode.You must administer it to use it in
MedPro mode.
For more information on the IP Interface capab ilities and limitations, refer to the

DEFINITY Enterprise Communications Server Release 8 Overview

.
The following sections desc ribe the process for
Installing in Media Processor Mode
Installing in IP Trunk Mode
Upgrading a TN802 V3 (or later) to a TN802B (MedPro mode)
!WARNING:

When connected remotely via p cANYWHERE, only use the pcANYWHERE

Restart Host Computer button on the toolba r to restart Windows NT.

Installing in Media Processor Mode

To operate in MedPro mode, you must install the TN802B IP Interface and, if the
system does not have one, you must also install and administer a TN799B C-LAN
circuit pack. For C-LAN ad ministration, refer to

DEFINITY Enterprise

Communications Server Administration for Network Connec tivity.

If you have existing TN802 IP Interface circuit p acks, you can up grade them
either by replacing the circuit pac k with a TN802B or by downloading the
TN802B firmware onto the circuit packs (see ‘‘Upgrade to TN802B (R8)’’ on page
6-76).