DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-21Upgrade the software and hardware
1
Release MMI (H/C only)
1. Type release board
cabinet carrier slot
and press Enter to release the
circuit packs, wh ich were busied out earlier.
Resolve Alarms
1. Type display alarms and press Enter to examine the alarm log. Resolve
any alarms that may exist using

DEFINITY Enterprise Communications

Server Release 8 Maintenance for R8r
.
Check Link Status
1. Type display communication-interface links and press Enter. Compare it
with the earlier status.
2. Type status link
number
and press Ente r. Repeat this step for each lin k.
Enable Scheduled Maintenance
1. Type change system-parameters maintenance and press Enter.
2. Type the appropriate time in the Start field to enable scheduled daily
maintenance. Make sure the Save Translation field is set to daily.
Enable Customer Options and Alarm Origination
to INADS
1. Get the DOSS order number of th e u pgrade from the project manager and
ask the regional Customer Software Administration to com plete the steps
in the shaded box. See ‘‘Where to Call for Technical Suppor t’’ on page -xx
for telephone numbers.
NOTE:
As part of the system registration p rocess, the INADS Database
Administrator enables Alarm O rigination and cust omer options.
2. When administration is completed , log in as craft at the Login: prompt.