DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Upgrading R5r/R6r/R7r to R8r without Adding Memory
2-19Upgrade the software and hardware
2
8. Type standard or daylight savings in the Type field, according to the
current time in the local time zone. For example, i f currently on standard
time, type standard.
9. Type the rule number in the Daylight Savings Rule field.
10. When all the information is correct, p ress Enter.
11. Type display time and press Enter to verify date and time data.
Set Core Dump Vector
1. Type set vector f spe-maint and press Enter to set the c ore dump vector to
perform a core dump on any system restart.
Enable TTI
NOTE:
Do this step only if the TTI is disabled and you want it enabled.
1. Type change system-parameters features and press Enter to chang e the
TTI field back to its value before the up grade.
Release MMI (H/C only)
1. Type release board
cabinet carrier slot
and press Enter to release the
circuit packs, wh ich were busied out earlier.
Resolve Alarms
1. Type display alarms and press Enter to examine the alarm log. Resolve
any alarms that may exist using

DEFINITY Enterprise Communications

Server Release 8 Maintenance for R8r
.
Check Link Status
1. Type display communication-interface links and press Enter. Compare it
with the earlier status.
2. Type status link
number
and press Ente r. Repeat this step for each lin k.
Enable Scheduled Maintenance
1. Type change system-parameters maintenance and press Enter.
2. Type the appropriate time in the Start field to enable scheduled daily
maintenance. Make sure the Save Translation field is set to daily.