DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-93Critical Reliability
5
For 2 Collocated Expansion Port Networks
1. Behind control carrier A of PPN cabinet 1:
■Install a lightwave transceiver on the c able connector at slot 1A 02.
■Connect a fiber optic cable to the transceiver jus t installed.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
2. Behind control carrier A of EPN cabinet 3:
■Install a lightwave transceiver on the c able connector at slot 3A 01.
■Connect the other end of the fib er cable to the transceiver just
installed.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
■At the top of the cabinet, c oil up the surplus fiber optic cable and
attach it to the wall of the cable t ray.
3. Behind control carrier B of PPN cabinet 1:
■Install a lightwave transceiver on the c able connector at slot 1B 02.
■Connect a fiber optic cable to the transceiver jus t installed.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
4. Behind port c arrier B of EPN cabinet 3:
■Install a lightwave transceiver on c able connector at slot 3B02.
■Connect the other end of the fib er optic cable to the li ghtwave
transceiver, just installed, at slot 3B02.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
■At the top of the cabinet, c oil up the surplus leng th of fiber optic
cable, and c arefully attach the coil to the wall of the c able tray.
5. Behind control carrier A of EPN cabinet 2:
■Install a lightwave transceiver on c able connector at slot 2A02.
■Connect 1 end of the fiber optic cable to the lightwave transc eiver,
just installed, at slot 2A02.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.