Connect the Modem
NOTE:
These instructions are for connecting the U.S. Robotics modem supplied to
U.S. customers only. If using a different modem, follow the manufac turer’s
instructions on connectin g the modem.
1. Connect the RS232 port of the modem to the MODEM connec tor of the
TN802B external cable assembly.
NOTE:
Check the labels near the co nnectors; the MODEM and COM2
connectors look the same.
2. Connect an analog telephone line to the left most analog-line port on the
modem as shown in Figure 6-21.
3. Make sure that the modem’s DIP switches are set as shown in
Figure 6-21 and Table 6-5.
4. Plug the modem into an AC power outlet.
5. Turn on the modem using the switch on the front of the mod em.
Figure 6-21. External Modem Connections for U.S. Robotics Modem
Figure Notes
1. Connect analog line here.
2. DIP switch 5 must be up.
3. Connect MODEM connector here.
4. Connect power c onnector here.
12345678
modfrobo KLC 030499