DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-46Add IP Interface Assembly
6
Prepare for Installation
Have the following equipment o n site before your shipment arrives:
AC power outlets for the modem and monitor.
Three unoccupied and adjoining por t slots in the DEFINITY ECS for the
TN802B IP Interface, if needed.
The TN802B occupies only one slot, but it nee ds the two slots to its left for
clearance.
An additional unocc upied por t slot for the TN799B, if needed. If you have
an existing TN799 circuit pac k, replace it with the TN799B.
A 10 BaseT or 10/100 BaseT Ethernet connection into your local area
network for the TN802B.
A 10 BaseT Ethernet connection into your local area netw ork for the
TN799B.
Two or more valid, unused IP addresses on your network (one for MedPro
and one for C-LAN) that can be as signed to the IP Interface server. You
also need the subnet mask and default gateway.
An analog telephone line reserved (DID is okay) for the IP Interface
diagnostic modem
A valid telephone number reserved for the IP Interface diagnostic modem
In addition if non-U.S. customer:
Modem comparab le to a U.S. Robotics Sportster Model USR 33.6 EXT.
Cable from modem to TN802B external cable assembly.
We recommend that you protect your c abinet with an uninterruptib le power
system (UPS).
Check your Shipment
When your DEFINITY ECS order arrives at your site, check the c ontents (see
Table 6-4).
1. Inspect the shipp ing carton for dama ge before opening it. If the box is
damaged,

do not open it

. Inform the shipping c ompany, and ask for
instructions on filing a c laim.
2. If the box is undamaged , check the conte nts against the packing slip.
Check the condition of eac h component, and note any damage or
shortages on the pack ing slip. The carton should contain the following for
each IP Interface ordered: