DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-46Add IP Interface Assembly
6
Prepare for Installation
Have the following equipment o n site before your shipment arrives:
■AC power outlets for the modem and monitor.
■Three unoccupied and adjoining por t slots in the DEFINITY ECS for the
TN802B IP Interface, if needed.
The TN802B occupies only one slot, but it nee ds the two slots to its left for
clearance.
■An additional unocc upied por t slot for the TN799B, if needed. If you have
an existing TN799 circuit pac k, replace it with the TN799B.
■A 10 BaseT or 10/100 BaseT Ethernet connection into your local area
network for the TN802B.
■A 10 BaseT Ethernet connection into your local area netw ork for the
TN799B.
■Two or more valid, unused IP addresses on your network (one for MedPro
and one for C-LAN) that can be as signed to the IP Interface server. You
also need the subnet mask and default gateway.
■An analog telephone line reserved (DID is okay) for the IP Interface
diagnostic modem
■A valid telephone number reserved for the IP Interface diagnostic modem
In addition if non-U.S. customer:
■Modem comparab le to a U.S. Robotics Sportster Model USR 33.6 EXT.
■Cable from modem to TN802B external cable assembly.
We recommend that you protect your c abinet with an uninterruptib le power
system (UPS).
Check your Shipment
When your DEFINITY ECS order arrives at your site, check the c ontents (see
Table 6-4).
1. Inspect the shipp ing carton for dama ge before opening it. If the box is
damaged,

do not open it

. Inform the shipping c ompany, and ask for
instructions on filing a c laim.
2. If the box is undamaged , check the conte nts against the packing slip.
Check the condition of eac h component, and note any damage or
shortages on the pack ing slip. The carton should contain the following for
each IP Interface ordered: