DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-9Read This First
5
Save Translations
1. Log in at the Manager II on the G2.
2. Type rtx (run tape, execute) and press Ent er. This instructs the system to
write all translation information from memory to the tap e.
3. Remove the system tape and install the bac kup tape.
4. Type rtx and press Enter.
Make Source Tape for TRACS Report
A spare G2 tape must be ac quired from the remediation b efore performing the
following steps. For each proc essor, there must always be 2 tapes on site with
the G2 system. Do not send a system or bac kup tape to STS. After performing
the previous proced ures, copy the G2 translations to the sp are tape used to
make the TRACS report.
1. Remove the backup tape and install the spare tape.
2. Type rtx and press Enter. This command i nstructs the system to write all
translation information from memory to the tape.
3. Remove the source tape.
4. Insert the system tape.
5. Mail the source tape (next-day d elivery) to STS for use in making the G2
TRACS rep ort.
System Upgrades
There are many configurations of DEFINITY G2 in the field. Each system can
have a unique configura tion. However, to simplify Release 8 upgrad es:
The existing common control is always rep laced by a multic arrier PPN
Existing traditional modules are rep laced by EPNs
Existing universal modules are upgraded to EPNs
A new multicarrier cabinet wo uld then always serve as the PPN. If a G2 universal
module is upgrad ed to a DEFINITY ECS Release 8 EPN, hardware changes
(including c arrier replacement) are required .