DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-17Upgrade the software and hardware
1
Upgrade Software
This command copies the so ftware from the removable media to the system dis k
and takes about 15 minutes to c omplete.
For standard reliability:
!CAUTION:

All calls are dropped—this is a service interruption.

1. Type upgrade software G3V8r.xx.x.xxx.x (entire alphanumeric string of
new software version) and press Ent er. At the prompt, press Enter to save
translations.
For high or critical reliab ility:
1. Type upgrade software G3V8r.xx.x.xxx.x no-calls (entire alphanumeric
string of new software version) and p ress Enter. At the prompt, press Enter
to save translations and attempt to p reserve calls across the interchang e.
For all reliabilities:
2. After the system resets, log in as craft.
3. Check for the Translation Corruption Detected message before
proceeding with th e upgrade. If c orruption is detected , refer to No
Translations After Upgrade in Appendix B, ‘‘Troubleshooting an Upgrade’’
to correct the problem.
!CAUTION:

Do not continue with the upgrad e until the translations errors are

corrected.

Reset SPE status (H/C only)
1. Type status SPE and press Enter. Wait until the Standby Handshake
field display s up, which takes about 3 minutes.
2. Type reset spe-standby 4 and press Enter.
NOTE:
You can c ont inue t he pr oces s whil e the SPE is res ettin g.
List Configuration Control
1. Type list configuration control and press Enter to verify the system
recognizes the third TN1650B Memory c ircuit pack.