DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-106Add a Switch Node Carrier (Standard Reliabi lity)
6
Reseat DEFINITY LAN Gateway System
1. Reseat the LAN Gateway assembly into its bac kplane connectors.
Reseat DEFINITY AUDIX System
1. Reseat the AUDIX assembly to its backplane c onnectors.
Power Up System
1. At the cabinet containing the new switch node c arrier, set the main circuit
break er to ON.
2. The system performs the level 4 rebooting process, loading the system
program and def ault or current translations from the disk. Rebooting takes
5 to 11 minutes.
NOTE:
Ignore alarms for now.
3. Type reset system 4 and press Enter to copy the translations from
removable media to memory.
4. Clear any alarms.
5. Type save translation and press Enter if translation changes were made in
Step 7 above.
6. Type restore disk full and press Enter to cop y the translations from
removable media to disk.
7. After the system reboot is finished and all trouble cleared, verify t hat the
EMERGENCY TRANSFER CONTROL switch is set to AUTO. This restores
the system to the normal operating mod e.
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select
Maintenance
.
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Restart System
from the
Reset System
menu.