Multicarrier G2 Universal Module to R8r EPN
5-112Critical Reliability
5
Resolve Alarms
Examine the alarm log. Resolve any alarms that may exist using
DEFINITY Enterprise Communications Server Release 8 Maintenance for R8si or DEFINITY Enterprise Communications Server Release 8 Maintenance for R8r
.
Enable Customer Options and Alarm Origination
1. Get the DOSS order number of th e u pgrade from the project manager and
ask the regional Customer Software Administration to com plete the steps
in the shaded box. See ‘‘Where to Call for Technical Suppor t’’ on page -xx
for telephone numbers.
NOTE:
As part of the system registration p rocess, the INADS Database
Administrator enables Alarm O rigination.
2. When administration is completed , log in as craft at the Login: prompt.
"init" login administration:
1. Log in as init.
2. Type change system-parameters customer-options and press Enter
to verify that the customer options are p roperly set.
3. Go to screen 6, QSIG Optional Features, and set the Basic Call
Setup field to y if the customer was using Supplementary Services
Protocol b or d on an ISDN-PRI trunk group before the up grade.
4. Type change system-parameters offer-options and press Enter.
5. If the Activate Offer field is n, set it to y and press Tab. A warning
message lets you know whether you need to save translations and
reboot to make the change p ermanent.
6. Press Enter to effect the ch anges or Cancel if there were no chang es.