DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-76Add IP Interface Assembly
6
Upgrade to TN802B (R8)
NOTE:
The upgrade takes about 20 minutes.
1. Insert the flash disk into the right most s lot on the TN802 IP trunk. On the
monitor, a dialog box assi gns a drive letter with the removab le media
designation; the default is D:.
2. Right click on Start > Explore to open the Windows N T Exploring pane
and select the drive letter i ndicated in step 1.
3. Double-click on Medpro and select the Setup ic on.
4. Follow the Install Shield procedure to transfer all the nec essary files to the
TN802 IP Interface.
NOTE:
In the Finish dialog box, selec t I will restart later. Do not
select Restart computer.
This would be a good tim e to read the Readme.txt file.
5. Click on Start > Settings > Control Panel > Services.
6. Select IP Trunk and click on Startup.
NOTE:
Do not click on Start.
7. Under Startup Type, select Disabled and click OK to disable IP Trunk
mode.
NOTE:
If IP trunk and MedPro services are both set to automatic , the
TN802B defaults to IP Trunk and MedPro features cannot be used.
8. Select MedPro and click on Startup.
NOTE:
Do not click on Start.
9. Under Startup Type, select Automatic and click OK to enable MedPro
mode.