9. Type change system-parameters features and press Enter. Use this
screen to change the TTI field bac k to its previous setting before the
upgrade.
10. When finished, place d ust covers over all exposed fib er couplings that
remain after the fiber optic c ables are removed.
11. If any fiber optic c ables were removed from Lightg uide Interconnect Units
(LIUs) or Fiber Patch Panels, remove the associated c able labeling. This
will prevent confusion if existing fiber is later moved.
12. Return all unused equipment (not owned by the customer) to Lucent
Technologies according to the req uirements outlined in:
BCS/Material Logistics, MSL/Attended Stocki ng Locations
Methods and Procedures for Basic Material Returns
13. If any message waiting lamps are on, skip to ‘‘Troubleshooting’’ on page
6-40.
Unadminister Fiber Links (Duplex Systems)
The fiber links routing to and from the EPN cabinet being removed must be
unadministered before removing
any
hardware from the cabinet.
!CAUTION:

Failure to unadminister fiber links before removing hardware causes

unnecessary alarm reports to INAD S and causes errors that are very

difficult to clear.

The fiber links are administered to matc h hardware and the Fiber Optic Ca ble
Running List. Fiber link administration creates translation data by identifying the
endpoint pairs for eac h link. To properly unadminister the fiber links, this
translation data must be removed .
1. Type list fiber and press Enter. All administered fib er connections are
displayed. Make note of the fi ber links to be removed.
2. Type change fiber link and press Enter. The Fiber Link Administration
screen appears. On screen 1:
a. Remove the Board Location: information for ENDPOINT-1 and
ENDPOINT-2. This is the cabinet, carrier, and slot that identifies the
physical location of an SNI or EI circu it pack that is the first
endpoint of the fiber link. Rep eat for the remaining endpoints.
b. The Board Type field is display only.