DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-33Standard Reliability
5
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interc onnect unit provided .
■Carefully attach the fiber cab le (with cable ties) to the wall of the
cable tray at the built-in cable tie positions.
■Coil up the surplus fiber cable and p lace it in the cable mana ger.
For Two Fiber-Remoted Expansion Port Networks
1. Behind control carrier A of PPN cabinet 1:
■Install a lightwave transceiver on c able connecto r at slot 1A02.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■Connect a fiber optic cable to the transc eiver just installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interc onnect unit provided .
■Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
2. Behind control carrier A of EPN cabinet 3:
■Install a lightwave transceiver on c able connecto r at slot 3A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■Connect a fiber optic cable to the transc eiver just installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interc onnect unit provided .
■Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
■Coil up the surplus fiber cable and p lace it in the cable mana ger.