DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-61High Reliability
5
Figure 5-17. Fiber Optic Connections EPN1 to EPN2
For Either One or Two Fiber-Remoted Expansion Port Networks
1. At control carrier A of PPN cabinet 1 (see Figure 5-19 through Figure
5-22):
Install a lightwave transceiver on the c able connector at slot 1A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
Connect a fiber optic cable to the transc eiver just installed.
Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
Connect the cable to the lig htguide interconnec t unit provided.
Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
Figure Notes
1. Lightwave Transceiver
2. To EPN Carrier A Slot 2A02
3. To EPN 1 Carrier A Slot 3A02
4.Fiber Optic Cable
5. RX Connection
6. TX Connection
cydff05CJL 10319
6
RXTX
2211