DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-61High Reliability
5
Figure 5-17. Fiber Optic Connections EPN1 to EPN2
For Either One or Two Fiber-Remoted Expansion Port Networks
1. At control carrier A of PPN cabinet 1 (see Figure 5-19 through Figure
5-22):
■Install a lightwave transceiver on the c able connector at slot 1A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■Connect a fiber optic cable to the transc eiver just installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the cable to the lig htguide interconnec t unit provided.
■Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
Figure Notes
1. Lightwave Transceiver
2. To EPN Carrier A Slot 2A02
3. To EPN 1 Carrier A Slot 3A02
4.Fiber Optic Cable
5. RX Connection
6. TX Connection
cydff05CJL 10319
6
RXTX
2211