DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-107Add a Switch Node Carrier (Standard Reliabi lity)
6
Resolve Alarms and Enable Alarm Origination
1. Examine the alarm log. Resolve any alarms using
DEFINITY Enterprise
Communications Server Release 8 Maintenance for R8r
.
2. If the Alarm Origination Activated field administration that you
previously noted is already set to y, be sure to enable Alarm Origination.
Otherwise you do not need to enab le Alarm Origination (proc eed to the
next section).
3. Type change system-parameters maintenance and press Enter.
The name of the Alarm Origination Activated field was changed to
Alarm Origination to OSS Numbers to support more than 1 OSS.
4. Type first-only in this field to enable Alarm Origination (to the first OSS,
which should be INADS).
Be sure to type y in both Cleared Alarm Notification and Restart
Notification fields. Press Enter.
5. Type save translation disk and press Enter.
If you have lost the previous administration of the Alarm Origination
field, you may register the system ag ain with the INADS Database
Administrator at the TSC. The INADS Administrator enables Alarm
Origination as part of the reg istration process.
!WARNING:
If you do not enable Alarm Orig ination when the customer has
purchased a services contract, the switch will not report any alarm to
the TSC automatically, causing the TSC to be unable to fulfill the
services contract.