DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-16Upgrade the software and hardware
1
Verify software version
NOTE:
The Tape Resident field shows the software load number. Write it down
for use later.
If standard reliability:
1. Type list configuration software-version and press Enter to verify that the
removable media contains the Release 8 softwa re. This takes about 2
minutes.
If high or critical reliab ility:
1. Type list configuration software-version long and press Enter to verify
that the removable media contain s the Release 8 software.
Save Translations
1. Type save translations tape and press Enter to save translat ions to the
new removable media, which ta kes about 2 minutes.
Save Announcements (if necessary)
1. Type save announce tape and press Enter to save announcements to the
new removable media.
Restore Disk
If standard reliability:
1. Type restore disk full and press Enter to write the new software to d isk.
Release 8 system software is now resident on the disk.
If high or critical reliab ility:
2. Type restore disk full both and press Enter to write the new software to
disk.
NOTE:
This command may take up to 25 minutes to c omplete. Until this
command finishes, the system p rovides no user feedbac k on the
system access screen. Do not press Enter wh ile the command
executes. Doing so cl ears the terminal screen as the comma nd
finishes, erasing any succ ess or failure messages the system may
provide.