DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Access Security Gateway
C-2Using the ASG Mobile
C
Using the ASG Mobile
1. Double click on the ASG Mobile V1.1 on your d esktop and an ASG Mobile
V1.1 Login window appears.
2. In the Tech ID field, type your login ID, whic h is the name of the attached
file (without the “.asg”). Your login ID is the same as your Lucent login (or
an abbreviated p art of it).
3. Type the password twice. Note that the passw ord is case-sensitive.
NOTE:
Your new password will be sent to you in a separate email.
4. Click the OK button and an ASG Mobile V1.1 Authentication wind ow
appears.
5. Use your communications pa ckage (for example, DNA, ProComm, or
TerraNova) to dial the switch you need to contac t.
6. Log into your communications p ackage window as either init, inads, or
craft. Instead of a password p rompt, a seven-digit (c hallenge) number
appears in the window of your c ommunications pac kage.
7. Move to the ASG Mobile V1.1 Authentication window.
8. Type the 10-digit Product ID in the Equipment ID field. The d efault ID is
10 zeros (0000000000).
9. Type init, inads, or craft in the Equipment Login field. The craft login ID
is the default.
10. Type the challenge number (from your c ommunications packag e window)
into the Challenge field. Do not use the “-” character.
11. Type the trouble ticket number in the Ticket Number field. If the re is no
ticket number, you can u se this field as a one-word comme nt field or leave
it blank.
12. Click the Star t button. The Activity Status field displays “Started” and
the Response field displays a new seven-digit number.
13. Move to your communications p ackage window.
14. Type the new seven-digit (response) number in th e Response field. Do
not use the “-” charac ter.
DEFINITY ECS verifies the response. If correct, DEFINITY logs you on. If
the response is incorrect, return to step 1. If this is the third rejection, see
the maintenance book for your system.