DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-56Add IP Interface Assembly
6
3. Type ping ip-address
nnn.nnn.nnn.nnn
board
UUCSS
and press Ente r.
The var iab le
nnn.nnn.nnn.nnn
is the IP address of another comput er
beyond the gateway and
UUCSS
is the cabinet, carrier, and slot of the
TN802B IP Interface.
The TN802B IP Interface is now installed in the DEFINITY carrier and connected
to the IP network.
Installing in IP Trunk Mode
NOTE:
IP Trunk mode should only be used to maintain comp atibility with existing
Release 7 IP Trunk or ITS-E installations. We strongly recommend that
MedPro mode be used whenever p ossible.
Prepare for Installation
Have the following equipment o n site before your shipment arrives:
A mouse, keyboard, and VGA monitor for use during the installation of the
server. You also need AC power outlets for the modem and monitor.
Three adjoining, unoccup ied port slots in the DEFINITY ECS
The TN802B IP Interface slides into only 1 slot, but its fac eplate occup ies
3 slots.
A 10 BaseT or 10/100 BaseT Ethernet connection into the custo mer’s local
area network (LAN)
A valid, unused IP address on the c ustomer’s LAN that can be assig ned to
the IP Interface server. You also need the subnet mask, default g ateway,
domain name, and so forth from the c ustomer’s network administrator.
An analog telephone line reserved for the IP Interface diagnostic modem
A valid telephone number reserved for the IP Interface diag nostic modem
If non-U.S. customer:
Modem comparab le to a U.S. Robotics, Inc. Sportster Mod el USR 33.6
EXT.
A cable from the modem to the TN802B external cable assembly.
We recommend that you protect the c abinet where the IP Interface is installed
with an uninterruptible p ower system (UPS).