DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Troubleshooting an Upgrade
B-12Troubleshooting Release 8 Upgrades
B
Software Incompatibility
If these procedures do no t clear the corruption p roblem, then the software
versions may be incomp atible. You may need to upgrade to an inte rim software
version before upgrad ing to the final software version.
1. Consult the remediation that came with the up grade software.
2. Contact your Lucent Technologies representative for this information.
Re-install the ISDN-PRI Links (Only for Failed Upgrades)
If your upgrade failed and you need to re-install the ISDN-PRI links, use this
procedure.
1. Type add data-module [PI ext] and press Enter.
2. Type the information in the fields based on the information that you
entered earlier.
3. Type change communication-interface links and press Enter.
4. Type the information in the fields based on the information that you
entered earlier with one exceptio n. Leave the Enable field setting as it is.
5. Type change communication-interface processor-channels and press
Enter.
6. Type the information in the fields based on the information that you
entered earlier.
7. Type change communication-interface links and press Enter.
8. Type the information in the Enable field based on the i nformation that you
entered earlier.
9. Type save translation and press Enter.