DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-113Critical Reliability
5
Save Translations
1. Type save translation and press Enter to get upg raded translations onto
disk. If the translations were corrup ted during the up grade, the following
error message displays when logging in:
!WARNING:
Translation corruption detected; c all Lucent Technologies distributo r
immediately.
NOTE:
The save translation c ommand cannot func tion if the translation
corruption message appears. See ‘‘Troubleshooting an Upgrade’’ on
page B-1.
Back Up Disk
1. Type backup disk and press Enter to backup all changed files.
2. Type test stored-data long and press Enter. This instructs the system to
verify the consistency of the MSS files (on the disk and removable media).
Return Replaced Equipment
Return replaced equip ment to Lucent Technologies accord ing to the
requirements outlined in:
BCS/Material Logistics, MSL/Attended Stocki ng Locations
Methods and Procedures for Basic Material Returns