DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-62High Reliability
5
2. Behind control carrier A of EPN cabinet 2:
■Install a lightwave transceiver on the c able connector at slot 2A 01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■Connect the fiber optic cable to the transceiver just installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the cable to the lig htguide interconnec t unit provided.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
■Coil up the surplus fiber cable and plac e it in the cable manager.
For 2 Fiber-Remoted Expansion Port Networks
1. Behind control carrier A of PPN cabinet 1:
■Install a lightwave transceiver on the c able connector at slot 1A 02.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■Connect a fiber optic cable to the transceiver jus t installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interco nnect unit provided.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.