DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-99Critical Reliability
5
For Either 1 or 2 Fiber-Remoted Expansion Port Networks
1. Behind control carrier A of PPN cabi net 1 (see Figure 5-33 through Figure
5-35):
Install a lightwave transceiver on the c able connector at slot 1A01.
Connect a fiber optic cable to the transc eiver just installed.
Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
Connect the fiber cab le to the lightguide interc onnect unit provided .
Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
2. Behind control carrier A of EPN cabinet 2:
Install a lightwave transceiver on the c able connector at slot 2A01.
Connect the fiber optic cable to the lightwave transceiver slot 2A01.
Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
Connect the fiber cab le to the lightguide interc onnect unit provided .
Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
Coil the surplus fiber optic cable and plac e it in the cable manag er.
3. Behind control carrier B of PPN cabinet 1:
Install a lightwave transceiver on the c able connector at slot 1B01.
Connect a fiber optic cable to the transc eiver just installed.
Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
Connect the fiber cab le to the lightguide interc onnect unit provided .
Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
4. Behind port carr ier B of EPN cabinet 2:
Install a lightwave transceiver on the c able connector at slot 2B02.
Connect the fiber optic cable to the transc eiver just installed.
Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
Connect the fiber cab le to the lightguide interc onnect unit provided .
Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
Coil the surplus fiber optic cable and plac e it in the cable manag er.