DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-99Critical Reliability
5
For Either 1 or 2 Fiber-Remoted Expansion Port Networks
1. Behind control carrier A of PPN cabi net 1 (see Figure 5-33 through Figure
5-35):
■Install a lightwave transceiver on the c able connector at slot 1A01.
■Connect a fiber optic cable to the transc eiver just installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interc onnect unit provided .
■Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
2. Behind control carrier A of EPN cabinet 2:
■Install a lightwave transceiver on the c able connector at slot 2A01.
■Connect the fiber optic cable to the lightwave transceiver slot 2A01.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interc onnect unit provided .
■Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
■Coil the surplus fiber optic cable and plac e it in the cable manag er.
3. Behind control carrier B of PPN cabinet 1:
■Install a lightwave transceiver on the c able connector at slot 1B01.
■Connect a fiber optic cable to the transc eiver just installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interc onnect unit provided .
■Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
4. Behind port carr ier B of EPN cabinet 2:
■Install a lightwave transceiver on the c able connector at slot 2B02.
■Connect the fiber optic cable to the transc eiver just installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interc onnect unit provided .
■Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
■Coil the surplus fiber optic cable and plac e it in the cable manag er.