DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Upgrading R5si/R6si to R8r EPN and Adding Memory
3-13Release 5/6si to Release 8r
3
Shut Down DEFINITY LAN Gateway System
!WARNING:
Neglecting to shut d own a DEFINITY LAN Gateway assembly before
powering down the system c abinet can damag e the LAN Gateway disk.
1. Log onto the DEFINITY LAN Gateway. S ee the
DEFINITY Communications
System Generic 3 Installation, Administration and Maintenance of
CallVisor ASAI over the DEFINITY LAN Gateway
for the procedure to log
on.
2. When the main menu appears, select
Maintenance
.
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Shutd own
from the
Reset Sys tem
menu.
5. Unseat the LAN Gateway assembly from its bac kplane connectors.
Shut Down DEFINITY AUDIX System
1. If a DEFINITY AUDIX System resides in the system to be upg raded, shut
down the AUDIX assembly and allow the d isk to completely spin down.
Refer to the ‘‘DEFINITY AUDIX Power Procedures’’ at the end of this
chapter.
!WARNING:
Neglecting to shut d own an AUDIX assembly before powering d own
the system cabinet where it resides can damage the AUDIX disk.
2. Unseat the AUDIX assembly from its backp lane connectors.
Power Down Existing System
1. At each PPN cabinet power sup ply, set the main circuit breaker to OFF.
!CAUTION:
Powering down the PPN will cause important system d ata, such as
BCMS data, records of queued ACD calls, Automatic Wakeup
requests, and Do Not Disturb req uests to be lost. Refer to DEFINITY
Enterprise Communications Server Release 8 Maintenance for R8r,
for information about prepa ring the system for a power down.
2. At each EPN cabinet power sup ply, set the main circuit breaker to OFF.