DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-133Add MCC Port Carriers
6
4. Type first-only in this field to enable Alarm Origination (to the first OSS,
which should be INADS).
Be sure to type y in both Cleared Alarm Notification and Restart
Notification fields. Press Enter.
NOTE:
The INADS Database Administrator enables Alarm Orig ination as
part of the registration proc ess.
!CAUTION:
If you do not enable Alarm Orig ination when the customer has purchased a services contract, the switch will not report any alarm to the TSC automatically, causing the TSC to be unable to fulfill the services contract.
Save Translations
1. If the system is high- or critic al-reliability, type status spe and press Enter
to verify that the standby SPE is refreshed and that the standb y disk is in
service.
2. Type save translation [spe-a or both] disk and press Enter. This
command instructs the system to take all translation information in
memory and write it to the disk(s).
3. If the MCC port network contains a TN750 Announc ement circuit pack,
type list configuration software-version and press Enter.
If screen 2 shows that recorded announcements were saved, these
announcements can be restored using the restore announcements
command. Type restore announcements and press Enter.
4. Type backup disk [spe-a or both] and press Enter. This command
instructs the system to bac kup the current information on disk to the
removable me dia.