555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-64Add IP Interface Assembly
6
Administration Steps
1. Log in as craft.
2. Type change circuit-pack and press Enter.
3. Check the Code colu mn to see if the slots above the TN802B say
DSMAPD or MEDPRO.
.
4. If MEDPRO, go to the entry just above the TN802B that says MEDPRO.
5. Type DSMAPD, and press Enter. Changing the one entry automatic ally
changes the entry abov e it. If it is in IP Trunk mode, you get the following
error message:
MedPro type requires TN802 with application. Type
MEDPRO on circuit-packs form.
Log onto the TN802B Interface Server
If administered remotely through p cANYWHERE:
1. Dial in to the server through pcANYWHERE using the dialup number
supplied.
2. Click on the pcANYWHERE Remote Host Computer button on the toolbar
to send CTRL ALT DEL to the host.
3. Type administrator in the User Name field.
4. Type iptrunk in the Password field and click OK.
5. After logging on for the first time, c hange the administrator p assword and,
if desired, the user name, to ensure sec urity. See your Windows NT server
documentation for details .
change circuit-packs Page 1 of 5
CIRCUIT PACKS
Cabinet: 1 Carrier: A
Carrier Type: processor
Slot Code Sf Mode Name Slot Code Sf Mode Name
11: DSMAPD RESERVED-IP
01: TN754 DIGITAL LINE 12: DSMAPD RESERVED-IP
02: TN758 POOLED MODEM 13: TN802 B MAPD BOARD
03: TN2144 ANALOG LINE 14:
04: TN746 B ANALOG LINE 15:
05 16:
06: TN771 C MAINTENANCE/TEST
07: TN464 F DS1 INTERFACE
08: TN2140 E&M TIE TRUNK
09: TN767 E DS1 INTERFACE
10: TN799 B CONTROL-LAN
’#’ indicates circuit pack conflict.