Upgrading R5r/R6r/R7r to R8r without Adding Memory
2-3Read This First
2
Software Upgrade
Release 8 software and translations are sa ved to remova ble media. Although the
translations automatically upd ate to Release 8, several features require special
attention because of screen c hanges or potential naming conflicts in the
process.
Between customer confirmation and the actual update or up grade, chec k the
screens to ensure the translations meet the cus tomer’s needs. After rebooting the
system, enter these translations either locally or remotely. If done remotely,
Contact Field Support Ad ministration Center (FSAC) for the remote entry. For
information to make the required c hanges, refer to:
DEFINITY Enterprise Communications Server Release 8 Administrator’ s
Guide
Required Tools
This upgrade may require the followin g tools and other items:
Wrist ground strap
Static-proof or original circ uit pack pac kaging for transporting circuit
packs
One copy of each of the foll owing books:
DEFINITY Enterprise Communications Server Release 8
Maintenance for R8r
DEFINITY Enterprise Communications Server Release 8
Administrator’s Guide
Antistatic Protection
!CAUTION:
When handling circuit p acks or any components of a DEFINITY ECS
system, always wear an antistatic wrist g round strap. Connect the strap to
an approved ground such as ground jac k on the DEFINITY ECS system.