DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
G3vs with Intel 386 or Risc Processor to R8r
4-10Remove the Present System
4
Disconnect Power and Ground
1. Disconnect the cab inet power cords from the rear of the c abinet.
2. Disconnect the 10 AWG (#25) (2.6 mm2) coupled bonding cond uctor wire.
3. Disconnect the 6 AWG (#40) (4.1 mm2) CABINET GROUND wire from the
ground bar in the c abinet.
Remove the Present System
1. Disconnect the management ter minal from the TERM connector.
2. Remove all of the 25-pair cables from the rear of the system. Retain any
cables that can b e reused with the Release 8r cabinet.
3. Remove the AC power cord from the system.
4. Remove the ground wires from the system. If the wires can reac h the
Release 8r cabinet, retain them for connec tion to the Release 8r system.