DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-32Standard Reliability
5
Figure 5-8. Collocated Fiber Optic Connections EPN1 to EPN2
For Either One or Two Fiber-Remoted Expansion Port Networks
1. At control carrier A of PPN cabinet 1. See Figure 5-5 through Figure 5-9.
Install a lightwave transceiver on the c able connector a t slot 1A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
Connect a fiber optic cable to the transc eiver just installed.
Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
Connect the fiber cab le to the lightguide interc onnect unit provided .
Carefully attach the cable (with c able ties) to the wall of the cab le
tray at the built-in cable tie positions.
2. Behind control carrier A of EPN cabinet 2:
Install a lightwave transceiver on c able connector at slot 2A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
Connect a fiber optic cable to the transc eiver just installed.
Figure Notes
1. Lightwave Transceiver
2. To PPN Carrier A Slot 2A02
3. To EPN 1 Carrier A Slot 3A02
4.Fiber Optic Cable
5. TX Connector
6. RX Connector
cydff05CJL 10319
6
RXTX
2211