DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-32Standard Reliability
5
Figure 5-8. Collocated Fiber Optic Connections EPN1 to EPN2
For Either One or Two Fiber-Remoted Expansion Port Networks
1. At control carrier A of PPN cabinet 1. See Figure 5-5 through Figure 5-9.
■Install a lightwave transceiver on the c able connector a t slot 1A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■Connect a fiber optic cable to the transc eiver just installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interc onnect unit provided .
■Carefully attach the cable (with c able ties) to the wall of the cab le
tray at the built-in cable tie positions.
2. Behind control carrier A of EPN cabinet 2:
■Install a lightwave transceiver on c able connector at slot 2A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■Connect a fiber optic cable to the transc eiver just installed.
Figure Notes
1. Lightwave Transceiver
2. To PPN Carrier A Slot 2A02
3. To EPN 1 Carrier A Slot 3A02
4.Fiber Optic Cable
5. TX Connector
6. RX Connector