Adding or Removing Cabinet Hardware
6-122Add a Switch Node Carrier (High or Critical Reliability)
6
Enable PNC Duplication
All non-duplicated SNIs to SNI fiber links are automatically dup licated.
1. Type change system-parameters customer-options and press Enter. On
screen 2, set the PNC Duplication? field to yes. Press Enter.
2. Type change system-parameters duplication and press Enter. Change
the Enable operation of PNC duplication? field to yes. Press
Enter.
3. Type status pnc and press Enter. Verify the Duplicated ? field is yes.
Resolve Alarms and Enable Alarm Origination
1. Examine the alarm log. Resolve any alarms using

DEFINITY Enterprise

Communications Server Release 8 Maintenance for R8r
.
2. If the Alarm Origination Activated field administration that you
previously noted is already set to y, be sure to enable Alarm Origination.
Otherwise you do not need to enab le Alarm Origination (proc eed to the
next section).
3. Type change system-parameters maintenance and press Enter.
The name of the Alarm Origination Activated field was changed to
Alarm Origination to OSS Numbers to support more than 1 OSS.
4. Type first-only in this field to enable Alarm Origination (to the first OSS,
which should be INADS).
Be sure to type y in both Cleared Alarm Notification and Restart
Notification fields if they are not enabled already. Press Enter.
5. Type save translation [spe-a or both] disk and press Enter.
If you have lost the previous administration of the Alarm Origination

field, you may register the system ag ain with the INADS Database
Administrator at the TSC. The INADS Administrator enables Alarm
Origination as part of the reg istration process.
!WARNING:

If you do not enable Alarm Orig ination when the customer has

purchased a services contract, the switch will not report any alarm to

the TSC automatically, causing the TSC to be unable to fulfill the

services contract.