DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
What’s New in Release 8.2r
xii
Verify Interchange
(H/C only) After the circuit pac ks have
been replaced in the first
carrier:
1. Type status spe and pre s s
Enter:
The Standby
Refreshed field shows
no
The Standby
Shadowing field shows
off
The Standby
Handshake field shows
up
After the circuit pac ks have
been replaced in the sec ond
carrier:
1. Type status spe and pre s s
Enter to make sure the
active side is ready for
interchange. When it is
ready,
The Standby
Refreshed field shows
yes
The Standby
Shadowing field shows
on
The Standby
Handshake field shows
up
Both SPEs show
functional
Because of the memory
mismatch between the
stand by a nd ac tive SPEs ,
typing the status spe
command yields two d ifferent
scenarios.
Upgrade other c arrier
(H/C only) To upgrade the other carri er,
lock the SPE sw itche s on th e
DUPINT to the other carrier.
The new active carrier resets
(cold 2 restart). Wait until the
login prompt appears then
log in.
Upgrade Software This command copies th e
software from the removable
media to the system disk and
takes about 15 minutes to
complete.
All calls are dropped—this is
a service interruption
Procedure Steps Notes