Adding or Removing Cabinet Hardware
6-35Remove an EPN Cabinet from an Existing System
6
3. Type change fiber link and press Enter. The Fiber Link Administration
screen appears. Use this sc reen to unadminister fiber links, eac h of which
is identified by a fib er number.
a. The Is one endpoint remoted via DS1 Converter
complex? field must remain administered.
b. Remove the location of the TN570 and the TN574 or TN1654 circuit
pack for both ENDPOINT-1 and ENDPOINT-2.
4. Scroll to screen 2.
a. Type no, as applicable, in each Facility Installed? field (A,
B, C, and D).
b. The Bit Rate: field must remain administered if other fib er
connections associated with the facility will remain.
c. The idle code in th e Idle Code MSB (1) . . . . LSB (8):
field must remain administered.
d. The Line Coding: field must remain administered.
5. For a T1 site, proceed to ‘‘T1 Installations Only’’. For an E1 site, proc eed to
‘‘E1 Installations Only’’.
T1 Installations Only
1. The Framing Mode: field is display only.
2. The DS1CONV-1 Line Compensation: and the DS1CONV-2 Line
Compensation: fields are display only.
3. Remove the Facility Circuit ID: from the facilities being
unadministered, if used. Press Ent er.
4. A display similar to the following appears after the proc edure is
completed:
RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED.
E1 Installations Only
1. The CRC? field must remain administered.
2. The Line Termination: fie ld is display only.
3. Remove the Facility Circuit ID information from the facilities being
unadministered, if used. Press Ent er.
4. A display similar to the following appears after the proc edure is
completed:
RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED.