DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-100Critical Reliability
5
For Two Fiber-Remoted Expansion Port Networks
1. Behind control carrier A of PPN cabinet 1:
Install a lightwave transceiver on the c able connector at slot 1A 02.
Connect a fiber optic cable to the transceiver jus t installed.
Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
Connect the fiber cab le to the lightguide interco nnect unit provided.
Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
2. Behind control carrier A of EPN cabinet 3:
Install a lightwave transceiver on c able connector at slot 3A01.
Connect the fiber optic cable to the transceiver just installed.
Route the fiber cable to the c able tray and down, out of the c abinet,
through the cable manag er to the PDS cross-connect facility.
Connect the fiber cab le to the lightguide interco nnect unit provided.
Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
Coil the surplus fiber optic cable and plac e it in the cable manager.
3. Behind control carrier B of PPN cabinet 1:
Install a lightwave transceiver on c able connector at slot 1B02.
Connect a fiber optic cable to the transceiver jus t installed.
Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
Connect the fiber cab le to the lightguide interco nnect unit provided.
Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
4. Behind port c arrier B of EPN cabinet 3:
Install a lightwave transceiver on the c able connector at slot 3B 02.
Connect the fiber optic cable to the transceiver just installed.
Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
Connect the fiber cab le to the lightguide interco nnect unit provided.
Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
Coil up the surplus fiber cable and plac e it in the cable manager.