DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-101Critical Reliability
5
5. Behind control carrier A of EPN cabinet 2:
■Install a lightwave transceiver on the c able connector at slot 2A 02.
■Connect a fiber optic cable to the transceiver jus t installed.
■Route the cable to the cable tr ay and down, out of the cab inet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interco nnect unit provided.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
6. Behind control carrier A of EPN cabinet 3:
■Install a lightwave transceiver on the c able connector at slot 3A 02.
■Connect the fiber optic cable to the transceiver just installed.
■Route the fiber cable to the c able tray and down, out of the c abinet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interco nnect unit provided.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
■Coil up the surplus fiber cable and plac e it in the cable manager.
7. Behind port c arrier B of EPN cabinet 2:
■Install a lightwave transceiver on the c able connector at slot 2B 03.
■Connect a fiber optic cable to the transceiver jus t installed.
■Route the fiber cable to the c able tray and down, out of the c abinet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interco nnect unit provided.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
8. Behind port c arrier B of EPN cabinet 3:
■Install a lightwave transceiver on the c able connector at slot 3B 03.
■Connect the fiber cab le to the transceiver just installed.
■Route the fiber cable to the c able tray and down, out of the c abinet,
through the cable manag er to the PDS cross-connect facility.
■Connect the fiber cab le to the lightguide interco nnect unit provided.
■Carefully attach the fiber optic cable (with cab le ties) to the wall of
the cable tray at the built- in cable tie positions.
■Coil up the surplus fiber cable and plac e it in the cable manager.