DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-94Add a Switch Node Carrier (Standard Reliabi lity)
6
Add a Switch Node Carrier (Standard Reliability)
To upgrade to a standard reliability R8r with Center Stage Switch (CSS), a switch
node carrier is add ed either to an empty ā€œ Eā€ carrier position of an existing
multicarrier port network or to the ā€œ Dā€ carrier po sition.
NOTE:
To avoid moving a port carrier, the p referred practice is to place the new
switch node carrier in an empty carrier position.
Service Interruption
1. Since the addition of the switc h node carrier requires a se rvice
interruption, notify the customer in ad vance as to when the add ition will
take place.
Verify System Status
1. Before proceeding, ex amine the system for alarms and correc t all
problems. The system must be alarm-free.
Disable Alarm Origination
1. Type change system-parameters maintenance and press Enter.
2. Make a note of the Alarm Origination Activated field
administration. If the feature is enabled , type n in this field to dis able
Alarm Origination.
!WARNING:

If you do not disable Alarm Origination before making c hanges to the

switch, the switch may g enerate alarms, resulting in unnecessar y

trouble tickets. Reducing redundant and unne cessary trouble

tickets.

NOTE:
For some releases of the software, disable Cleared Alarm
Notification and Restart Notification fields before
submitting the form.