MGC Manager User’s Guide - VoicePlus Edition

The following table lists the system.cfg flags you can check and modify.

Table 8-2: ReadiRecorder system.cfg Flags

Section / Default Flags and Values

Required Description Value

Audio Plus

SINGLE_PARTY_HEARS_MUSIC = NO

NO

No need for background

 

 

music.

 

 

 

AUDIO_PLUS_CM_MSG_32 = 64

64

Affects the

 

 

ReadiRecorder’s IVR

 

 

Messages Status report.

 

 

The default is the

 

 

maximum number of

 

 

IVR messages that can

 

 

be downloaded for a

 

 

given group (in this case

 

 

64 messages of 32-

 

 

second duration).

 

 

 

CDR

 

 

 

 

 

CDR = YES

YES

Enables viewing the

 

 

CDRs list for the

 

 

ReadiRecorder. When

 

 

disabled, the CDRs do

 

 

not include records that

 

 

were written to the

 

 

ReadiRecorder disk.

 

 

 

External DB

 

 

 

 

 

ENABLE_EXTERNAL_DB_ACCESS = NO

YES

Allows the definition of

 

 

an external database for

 

 

the Web site user

 

 

authentication.

 

 

Note: If you enable this

 

 

function, set the other

 

 

flags in this section. For

 

 

more information, see

 

 

the External DB Tools

 

 

documentation.

 

 

 

8-23

Page 371
Image 371
Polycom DOC2066F manual Audio Plus, External DB