ProSecure Unified Threat Management (UTM) Appliance

The following figure shows the product label for the UTM25S:

Figure 18.

Choose a Location for the UTM

The UTM is suitable for use in an office environment where it can be freestanding (on its runner feet) or mounted into a standard 19-inch equipment rack. Alternatively, you can rack-mount the UTM in a wiring closet or equipment room. A rack-mounting kit, containing two mounting brackets and four screws, is provided in the package for the multiple WAN port models.

Consider the following when deciding where to position the UTM:

The unit is accessible, and cables can be connected easily.

Cabling is away from sources of electrical noise. These include lift shafts, microwave ovens, and air-conditioning units.

Water or moisture cannot enter the case of the unit.

Airflow around the unit and through the vents in the side of the case is not restricted. Provide a minimum of 25-mm or 1-inch clearance.

The air is as free of dust as possible.

Temperature operating limits are not likely to be exceeded. Install the unit in a clean, air-conditioned environment. For information about the recommended operating temperatures for the UTM, see Appendix H, Default Settings and Technical Specifications.

Note: For the UTM9S and UTM25S, see also Wireless Equipment

Placement and Range Guidelines on page 579.