MMB

CHAPTER 3 Web-UI Operations

Item

Description

Power System

Redundancy status of power supply units:

Redundancy

• Redundant: PSU redundancy is maintained.

 

[Non-redundant: FSufficient Resources]: PSU redundancy is

 

lost, but there are enough PSUs to continue system operation.

 

[Non-redundant: Insufficient Resources]: PSU redundancy is

 

lost, and there are not enough PSUs to continue system

 

operation.

 

 

UPC#x

UPS status detected by the UPC interface:

 

• AC Lost: Power is off.

 

• Battery Lost: The battery has been depleted.

 

• Failed: The system has failed.

 

-: Normal status or the UPS is not connected.

 

 

PSU

 

PSU

PSU number

Status

PSU status:

 

• OK: Operating normally

 

• Not present: Not installed

 

• Failed: Failure

 

• Predictive Fail: Expecting a failure.

 

• A/C Lost: Power failure

 

 

Power Status

Indication of whether PSU power is On or Off

Part Number

PSU part number

Serial Number

PSU serial number

(1) Menu operation

[System] [Power Supply]

(2)GUI operation

None

3-28

C122-E003-02EN