GSWB
CHAPTER 8 CLI Operations
Interfaces whose information is displayed:
zIO_Unit 0
zGigabitEthernet
zTenGigabitEthernet
z
Displayed names:
zspeed/duplex/flow: Line speed, duplex mode, and flow control when communication is ready
-Line speed (bps): 10M/100M/1G/10G
-Duplex mode: FULL (full duplex) or HALF (half duplex)
-Flow control: SEND (transmission), RECV (reception), BOTH (transmission/ reception) or OFF (no control)
zup / down:
-up: Communication ready
-down: Communication not ready
(6)Error Messages
•% Incomplete command.
Cause: Incomplete command input
Action: Enter the command string correctly.
• % Invalid input detected at '^' marker.
Cause: Invalid character detected at '^' marker in the entered command string
Action: Enter the command string correctly.
• System error.
Cause: An internal error occurred.
Action: Check the system status, and reenter the command. If the error occurs again, collect unit information, configuration definition information, and the information in different types of logs, and restart the unit. Alternatively, contact a certified service engineer.