PSA

 

 

 

6.2 SAF-TE Operation Command (diskctrl)

 

 

 

 

 

 

 

 

 

Message

Meaning

Response

 

FJSVpsa: E 02167 diskctrl Invalid

An invalid option was

Specify correct options.

 

option

specified.

 

 

 

 

 

 

FJSVpsa: E 02169 diskctrl too

Incorrect number of

Specify correct options.

 

few or more option

command options.

 

 

 

 

 

 

FJSVpsa: E 02170 diskctrl Cannot

HDD rotation stop

Retry. If an error recurs, check

 

stop HDD

failed.

whether the device is already offline

 

 

 

because of failure.

 

 

 

 

 

FJSVpsa: E 02171 diskctrl Cannot

Device information

Check the HDD information

 

get device information

acquisition failed.

recognized by the OS. If no sg exists

 

 

 

under /dev, load the sg driver using

 

 

 

modprobe and then retry.

 

 

 

 

 

FJSVpsa: E 02173 diskctrl sg

sg (SAF-TE device)

Load the sg driver using modprobe

 

device not found

cannot be found.

and then retry.

 

 

 

 

 

FJSVpsa: E 02174 diskctrl Device

The specified device is

Check for the presence of the device

 

not found

not found.

and specify the correct device name.

 

 

 

If no sg exists under /dev, load the sg

 

 

 

driver using modprobe and then retry.

 

 

 

 

 

FJSVpsa: E 02175 diskctrl SAF-

A command on the SAF-

Retry. If an error recurs, the SAF-TE

 

TE access failed (Read Enclosure

TE device encountered

device may be faulty. Check for an

 

Configuration)

an error.

sg error. Perform replacement or

 

 

 

other action.

 

 

 

 

 

FJSVpsa: E 02176 diskctrl SAF-

A command on the SAF-

Retry. If an error recurs, the SAF-TE

 

TE access failed (Read Enclosure

TE device encountered

device may be faulty. Check for an

 

Status)

an error.

sg error. Perform replacement or

 

 

 

other action.

 

 

 

 

 

FJSVpsa: E 02177 diskctrl SAF-

A command on the SAF-

Retry. If an error recurs, the SAF-TE

 

TE access failed (Read Device

TE device encountered

device may be faulty. Check for an

 

Slot Status)

an error.

sg error. Perform replacement or

 

 

 

other action.

 

 

 

 

 

FJSVpsa: E 02186 %s is busy.

A power-off instruction

Issue the power-off instruction later.

 

Please retry after a few minutes.

was issued to a busy

 

 

 

device.

 

 

 

 

 

 

FJSVpsa: E 02187 internal error

An internal error

Contact a certified service engineer.

 

 

occurred.

 

 

 

 

 

C122-E003-02EN

6-7