GSWB
CHAPTER 8 CLI Operations
• System error.
Cause: An internal error occurred.
Action: Check the system status, and reenter the command. If the error occurs again, collect unit information, configuration definition information, and the information in different types of logs, and restart the unit. Alternatively, contact a certified service engineer.
8.3.11.2 show ip igmp snooping mrouter
This command displays information about the multicast router interface that has been dynamically learned or manually set.
(1) Synopsis
show ip igmp snooping mrouter [vlan
(2) Options
zvlan
Specifies the VLAN ID whose interface information is to be displayed.
If this parameter is omitted, the interface information on all VLANs defined on the switch is displayed.
(3)Command mode enabled exec
user exec
(4) See also
ip igmp snooping