GSWB

CHAPTER 8 CLI Operations

(6)Error Messages

% Incomplete command.

Cause: Incomplete command input

Action: Enter the command string correctly.

• % Invalid input detected at '^' marker.

Cause: Invalid character detected at '^' marker in the entered command string

Action: Enter the command string correctly.

Internal communication error.

Cause: An internal error occurred.

Action: Check the system status, and reenter the command. If the error occurs again, collect unit information, configuration definition information, and the information in different types of logs, and restart the unit. Alternatively, contact a certified service engineer.

• Input parameter error.

Cause: The specified [engineid-string] is invalid.

Action: Enter a correct value.

8.2.17.2 snmp-server location

This command specifies the installation location of a local device. The default value is "none".

(1)Synopsis

Specifies the installation location of a local device

snmp-server location <location>

Resets this setting to the default value no snmp-server location

(2)Options

z<location>:

The string entered for the installation location consists of 1 to 64 en-size alphanumeric characters and symbols, which may include _ - . and @.

8-114