GSWB 7.9 Spanning Tree Menu

Table 7.82 Displayed and setting items in the [STP Status (Bridge status)]

window

Item

 

Description

Bridge: Bridge information

 

 

status

STP setting status, either STP enabled or STP disabled:

 

Enable: STP enabled

 

Disable: STP disabled

 

 

Bridge Identifier: Device

identification information

priority

Bridge priority value of the device:

 

• Displayed range: 0 to 65535

 

 

address

Device MAC address

Root Bridge Identifier: Root bridge information

priority

Bridge priority of the bridge unit specified as the root bridge:

 

• Displayed range: 0 to 65535

 

 

address

MAC address of the bridge unit specified as the root bridge

Root port

Interface name of the unit specified as the root port. The following

 

interface types can be used:

 

• GigabitEthernet 0/1 to 0/8

 

• I/O units 00 to 71

 

• TenGigabitEthernet 1/1 to 1/2

 

Port-channels 1 to 7

 

If the interface works as a root bridge, "0" is displayed as the port

 

number and nothing is displayed as the interface name.

 

 

cost of root path

Path cost from the device to the root bridge:

 

• Displayed range: 0 to 2147483647

 

 

Topology change: Flag ("set" or "not set" is displayed)

flag

Topology change flag (set or not set).

detected flag

Topology change detection flag (set or not set).

Times: Values of timers in use (These are not displayed when the topology is being changed.)

hold

Config BPDU transmission holding period

topology change

Topology change flag storage period in Config BPDU

notification

TCN BPDU transmission interval when a topology change is

 

detected

 

 

hello

Config BPDU transmission interval

max age

Maximum aging time

forward delay

Transfer delay time

Configured Times: Specified values based on configuration definitions (These are not

displayed when the topology is being changed.)

 

 

hello time

Config BPDU transmission time:

 

Interval value range: 1 to 10

 

 

max age

Maximum aging time:

 

Displayed range: 6 to 40

 

 

 

C122-E003-02EN