GSWB 8.2 Configuration Definition Commands

(6)Error Messages

% Incomplete command.

Cause: Incomplete command input

Action: Enter the command string correctly.

• % Invalid input detected at '^' marker.

Cause: Invalid character detected at '^' marker in the entered command string

Action: Enter the command string correctly.

Internal communication error.

Cause: An internal error occurred.

Action: Check the system status, and reenter the command. If the error occurs again, collect unit information, configuration definition information, and the information in different types of logs, and restart the unit. Alternatively, contact a certified service engineer.

• Input parameter error.

Cause: An invalid IP address was specified.

Action: Enter the correct IP address.

• Input parameter duplicate error.

Cause: Duplicated registration of the same connection conditions was attempted.

Action: Check the remote connection conditions already registered.

• Set count over.

Cause: Registering 101 or more connection conditions was attempted.

Action: Check the remote connection conditions already registered.

• Entry isn’t existed.

Cause: Deletion of an unregistered remote connection condition was attempted.

Action: Check the remote connection conditions already registered.

C122-E003-02EN

8-109