GSWB

CHAPTER 8 CLI Operations

• % Invalid input detected at '^' marker.

Cause: Invalid character detected at '^' marker in the entered command string

Action: Enter the command string correctly.

• System error.

Cause: An internal error occurred.

Action: Check the system status, and reenter the command. If the error occurs again, collect unit information, configuration definition information, and the information in different types of logs, and restart the unit. Alternatively, contact a certified service engineer.

8.3.6Bridge-related commands

8.3.6.1show bridge

This command displays the learning table contents.

The displayed contents include Dynamic entries and Static entries.

The command cannot be executed during execution of any of the following commands:

zclear bridge

zThis command

Any change in the learning table is reflected in the displayed information after about 5 to 10 seconds.

(1)Synopsis

Displays the learning table contents

show bridge {[<interface-id>] address <address>}

[vlan <vlan-id>] [status <status>] [chip <chip no>]}

(2) Options

z<interface-id> (optional): Specifies the interface of the contents to be displayed.

-GigabitEthernet 0/1-8

-IO_Unit 0 0-7 1

-TenGigabitEthernet 1/1-2

-port-channel 1-7

8-222