MMB 3.2 System Menu

3.2.5System Setup window

The [System Setup] window allows you to specify PRIMEQUEST Power Feed mode settings and Power Restore actions.

Figure 3.7 System Setup window

Table 3.13 Displayed and setting items in the [System Configuration] window

Item

Description

Power Feed Mode

The user can set either single power feed mode or dual power feed

 

mode for the power supply to the PRIMEQUEST-series machine:

 

• Single: Single power feed mode

 

• Dual: Dual power feed mode

 

The default setting is [Single].

 

 

Power Restoration

The user can specify the action taken for power recovery in the

Policy

event of a power failure, and this setting is displayed:

 

• Always off: Keeps power off after power recovery.

 

• Always on: Turns power on after power recovery regardless of

 

the status at the time of the power failure.

 

• Restore: Restores the status at the time of the power failure.

 

That is, if power was on at the time of the power failure, power

 

is turned on, and if power was off, power is kept off.

 

The default setting is [Restore].

 

 

C122-E003-02EN

3-21