MMB 3.2 System Menu

3.2.9Fans window

The [Fans] window displays fan statuses in the PRIMEQUEST-series machine, and the fan statuses can be cleared using this window.

The temperatures at the air intake and exhaust temperature sensors and at the CPU temperature sensor are displayed.

Figure 3.11 [Fans] window

Table 3.20 Displayed items in the [Fans] window

Item

Description

Fan Speed Mode

Fan speed mode:

 

• Normal: Normal rotational speed

 

High-speed: High rotational speed (The fan entered high-speed

 

mode because of an abnormal temperature or lost redundancy.)

 

 

Fan Redundancy

Fan redundancy status:

 

• Redundant: Fan redundancy is maintained.

 

Non-redundant: Sufficient Resource Fan redundancy is lost, but

 

there are enough fans to continue system operation.

 

Non-redundant:Insufficient Resources: Fan redundancy is lost,

 

and there are not enough fans to continue system operation.

 

 

FAN-TRAY#

Fan tray number

Part Number

Fan tray part number

Serial Number

Fan tray serial number

FAN#

Fan number

C122-E003-02EN

3-29