MMB

CHAPTER 3 Web-UI Operations

Table 3.73 Displayed and setting items in the [ASR (Automatic Server

Restart) Control] window

Item

 

Description

Number of Restart Tries

Specify the number of OS restarts attempted following a timeout

 

due to the Boot Watchdog or PSA software watchdog.

 

The setting range is 0 to 10.

 

The default setting is 5.

 

 

Action after exceeding

Specify the action to be taken if the repeated restart attempts due to

Restart tries

a watchdog timeout or other causes exceed the above number of

 

retries.

 

The action types are as follows:

 

• Stop rebooting and Power Off

 

Stop rebooting

 

Diagnostic Interrupt assert

 

The default setting is [Stop rebooting and Power Off].

 

 

Automatic Power On

Specify the delay time before the power-on operation in an

Delay

automatic restart.

 

The setting range is 0 to 10 minutes.

 

The default setting is 0 minutes.

 

 

Cancel Boot Watchdog

Select [Cancel Boot Watchdog] to disable OS boot monitoring.

 

By default, the check box is unchecked.

 

Note: OS boot monitoring is a PSA function. The monitoring

 

 

starts when the Boot Watchdog timeout time is set in the

 

 

PSA window. If the specified Boot Watchdog timeout time

 

 

is too short, however, a timeout may occur before the system

 

 

starts PSA, which can stop the Boot Watchdog timer. As a

 

 

result, repeated reboots may occur. In such cases, PSA has

 

 

not yet started, and the PSA page that provides the Boot

 

 

Watchdog function cannot be displayed, so the Boot

 

 

Watchdog cannot be displayed. Provided as a measure

 

 

against this problem, this check box disables the Boot

 

 

Watchdog without using PSA.

 

 

 

Table 3.74 Buttons in the [ASR (Automatic Server Restart) Control] window

Button

Description

Apply

Click the [Apply] button to:

 

• Set the specified values in items such as [Number of Restart

 

Tries] [Action after exceeding Restart tries].

 

• Disable the Boot Watchdog if the [Cancel Boot Watchdog]

 

check box is checked.

 

 

Cancel

Click the [Cancel] button to revert to the original settings.

3-104

C122-E003-02EN