GSWB 8.3 Operation Commands

(4) See also

wrr-queue cos-map

(5)Examples

Displays output of show wrr-queue cos-map

Switch# show wrr-queue cos-map

CoS Value : 0 1 2 3 4 5 6 7

Priority Queue : 0 0 1 1 2 2 3 3

Switch#

zCoS Value

CoS value (always in a range of 0 to 7)

zPriority Queue

Queue ID of the CoS priority queue. This setting (range of 0 to 3) is for a CoS value (range of 0 to 7).

(6)Error Messages

% Incomplete command.

Cause: Incomplete command input

Action: Enter the command string correctly.

• % Invalid input detected at '^' marker.

Cause: Invalid character detected at '^' marker in the entered command string

Action: Enter the command string correctly.

• System error.

Cause: An internal error occurred.

Action: Check the system status, and reenter the command. If the error occurs again, collect unit information, configuration definition information, and the information in different types of logs, and restart the unit. Alternatively, contact a certified service engineer.

C122-E003-02EN

8-265