GSWB

CHAPTER 8 CLI Operations

(6)Error Messages

% Incomplete command.

Cause: Incomplete command input

Action: Enter the command string correctly.

• % Invalid input detected at '^' marker.

Cause: Invalid character detected at '^' marker in the entered command string

Action: Enter the command string correctly.

• File error.

Cause: The specified file is corrupt.

Action: Download the correct file.

• Open error.

Cause: The file has not been downloaded yet.

Action: Download the correct file.

• Command is already running.

Cause: Execution of one of the following commands is in progress:

clear ramdisk, install, show system information, tftp, change, reload.

Action: Reenter the command after the current command exits.

Bank cannot be switched.

Cause: Installation failed.

Action: Turn off power to the GSWB to shut it down, remove the GSWB from the cabinet, reinstall the GSWB in the cabinet, and then retry the operation. If the error occurs again, collect unit information, configuration definition information, and the information in different types of logs, and then restart the unit. Alternatively, contact a certified service engineer.

• System error.

Cause: An internal error occurred.

Action: Check the system status, and reenter the command. If the error occurs again, collect unit information, configuration definition information, and the information in different types of logs, and restart the unit. Alternatively, contact a certified service engineer.

8-168

C122-E003-02EN